Rockwill Inverter Platform
brief introduction
Leveraging Rockwill industry leading PV inverter platform, the Rockwill platform is a turnkey utility-grade multi-megawatt platform, complete with factory integrated step-up transformers, ring main unit (RMU), and power conversion electronics.
Rockwill platform is a turnkey utility-ready building block for PV installations. Installation is as simple as placing the unit by crane and connecting both ends. Because Roockwill platform is factory integrated, customers save money on field integration labor. Rockwill platform is standard 40 foot container size which can be easily transported.
designed to switch!
Specifications |
1.0 MW |
1.5 MW |
2.0MW |
---|---|---|---|
Input parameters |
|||
Input Voltage Range |
650-850 VDC |
515-850 VDC |
650 - 850 VDC |
Maximum Array Input Voltage |
1000 VDC |
1000 VDC |
1000 VDC |
maximum operating input current* |
1744 ADC |
3160 ADC (2*1580 ADC) |
3488 ADC (2*1744 ADC) |
PV Array Configuration |
Negative/Positive |
Negative/Positive |
Negative/Positive |
DC Input Combiner Options |
|||
Combiner Bus Bar Input |
12 |
24 (2*12) |
24 (2*12) |
Number of Inputs and Fuses |
12 * 250A |
12 * 250A |
24 * 250A |
Transfomer |
|||
Integrated MV Transfomer |
Customer Specified |
Customer Specified |
Customer Specified |
Efficiency |
|||
Inverter Maximum** |
98.7% |
98.7% |
98.7% |
European - Eta *** |
98.5% |
98.5% |
98.5% |
Output Parameters | |||
Nominal Power |
1.0 MW |
1.5 MW |
2.0 MW |
Nominal Output Voltage |
400 VAC |
320 VAC |
400 VAC |
Output Voltage Range |
320 - 460 VAC |
256 - 368 VAC |
320 - 460 VAC |
Maximum Output Current/Phase |
1587 A |
1488 A (per 750KW) |
1587 A (per 1MW) |
Standby Consumption (tare losses including control power and aux.) |
150W |
300W |
300W |
Nominal Output Frequency, 3-Phase |
50/60 Hz |
50/60 Hz |
50/60 Hz |
Maximum Harmonic Distortion |
<3% THD |
<3% THD |
<3% THD |
Power Factor, Full Load |
> 99% |
> 99% |
> 99% |
Dynamic Power Fcator Control |
+/- 0.8 |
+/- 0.8 |
+/- 0.8 |
Power Curtailment |
0-100%, 1% step |
0-100%, 1% step |
0-100%, 1% step |
Environment |
|||
Operating Temp Range (Nominal Power) |
-30 C~+55C |
-30 C~+55C |
-30 C~+55C |
Storage Temp Range |
-30 C~+70C |
-30 C~+70C |
-30 C~+70C |
Cooling |
Forced |
Forced |
Forced |
Noise Level (Distance of 3m) |
< 65 dB (A) |
< 65 dB (A) |
< 65 dB (A) |
Relative Humidity (Non-Condensing) |
15 ~ 95% |
15 ~ 95% |
15 ~ 95% |
Elevation (Max***) |
4,000 m |
4,000 m |
4,000 m |
Enclosure |
|||
Dimensions (HxWxD) |
2103*2795*945mm |
2103*4585*945mm |
2103*2795*945mm |
Weight |
12,500kg |
15,500kg |
15,500kg |
Finish |
RAL 7035 |
RAL 7035 |
RAL 7035 |
Hood and Base Trim Finish |
RAL 5001 |
RAL 5001 |
RAL 5001 |
Protection Rating |
NEMA 3R/IP54 |
NEMA 3R/IP54 |
NEMA 3R/IP54 |
Warranty and Services |
|||
Five Year Warranty |
Standard |
||
Extended Warranty (1 ~ 5yrs) |
Optional |
||
Preventive Maintenance Agreement |
Optional |
||
Communication Interface |
|||
Modbus RS485 |
Standard |
||
Modbus TCP/IP |
Optional |
||
Regulations and Standards Conformity |
|||
CE marks, VDE mark, Low Voltage Directive 2006/95/CE, EN 62116, EN 62093, IEC62109-1, IEC62109-2 |
Standard |
||
Adavanced Grid Support (Incl. LVRT/DBEW)Option |
Option |
||
RD 1699 |
Standard |
||
ENEL Connection Guidelines |
Standard |
All rights Reserved to Rockwill Electric Company